Dry barrel fire hydrant from TPMC is designed to drain water from its barrel when not in service. This freeze-resistant design suits all climates including freezing areas, and ensures dependable fire protection service in cold environments.
Available size (Source 1 with UL/FM)
| Inlet size | Way of outlet | Hose outlet | Pumper outlet | Flanged monitor elbow | Ref. No. |
|---|---|---|---|---|---|
| 6″ | 2-way | (2) 2-1/2″ NH | / | / | F0201 (UL/FM) |
| 6″ | 2-way | (2) 2-1/2″ NH | / | 3″ or 4″ | F0202 (UL/FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 4″ NH | / | F0203 (UL/FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 4″ NH | 3″ or 4″ | F0204 (FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 4-1/2″ NH | / | F0205 (UL/FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 4-1/2″ NH | 3″ or 4″ | F0206 (FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 5″ NH | / | F0207 (UL/FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 5″ NH | 3″ or 4″ | F0208 (FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 5″ Storz | / | F0209 (UL/FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 5″ Storz | 3″ or 4″ | F0210 (FM) |
| 6″ | 4-way | (4) 2-1/2″ NH | / | / | F0211 (UL/FM) |
| 6″ | 4-way | (4) 2-1/2″ NH | / | 3″ or 4″ | F0212 (FM) |
| 6″ | 4-way | (3) 2-1/2″ NH | (1) 4″ NH | / | F0213 (UL/FM) |
| 6″ | 4-way | (3) 2-1/2″ NH | (1) 4″ NH | 3″ or 4″ | F0214 (FM) |
| 6″ | 4-way | (3) 2-1/2″ NH | (1) 4-1/2″ NH | / | F0215 (UL/FM) |
| 6″ | 4-way | (3) 2-1/2″ NH | (1) 4-1/2″ NH | 3″ or 4″ | F0216 (FM) |
| 6″ | 4-way | (3) 2-1/2″ NH | (1) 5″ NH | / | F0217 (UL/FM) |
| 6″ | 4-way | (3) 2-1/2″ NH | (1) 5″ NH | 3″ or 4″ | F0218 (FM) |
| 6″ | 4-way | (3) 2-1/2″ NH | (1) 5″ Storz | / | F0219 (UL/FM) |
| 6″ | 4-way | (3) 2-1/2″ NH | (1) 5″ Storz | 3″ or 4″ | F0220 (FM) |
| 6″ | 4-way | (2) 2-1/2″ NH | (2) 4″ NH | / | F0221 (UL) |
| 6″ | 4-way | (2) 2-1/2″ NH | (2) 4″ NH | 3″ or 4″ | F0222 (ISO) |
| 6″ | 4-way | (2) 2-1/2″ NH | (2) 4-1/2″ NH | / | F0223 (UL) |
| 6″ | 4-way | (2) 2-1/2″ NH | (2) 4-1/2″ NH | 3″ or 4″ | F0224 (ISO) |
| 6″ | 4-way | (2) 2-1/2″ NH | (2) 5″ NH | / | F0225 (UL) |
| 6″ | 4-way | (2) 2-1/2″ NH | (2) 5″ NH | 3″ or 4″ | F0226 (ISO) |
| 6″ | 4-way | (2) 2-1/2″ NH | (2) 5″ Storz | / | F0227 (UL) |
| 6″ | 4-way | (2) 2-1/2″ NH | (2) 5″ Storz | 3″ or 4″ | F0228 (ISO) |
Note:
1. The inlet base flange is available with ANSI B16.1 Class 125.
2. It may incorporate a 3″ or 4″ flanged monitor elbow (ASME B16.1 Class 125), so to connect additional fire monitor.
3. Traffic type (With breakable flange) breaks cleanly upon impact to protect the remainder of the hydrant from damage.
4. It is equipped with an exclusive fire hydrant wrench, see TPMC Ref. No. F6851.
Available size (Source 2 with UL/FM)
| Inlet size | Way of outlet | Hose outlet | Pumper outlet | Flanged monitor elbow | Ref. No. |
|---|---|---|---|---|---|
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 4″ NH | / | F0231 (FM) |
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 4-1/2″ NH | / | F0232 (UL/FM) |
Note:
1. The inlet base flange is available with ANSI B16.5 Class 150, or EN 1092 PN 16 (BS 4504 / DIN 2501, PN 16).
2. Traffic type (With breakable flange) breaks cleanly upon impact to protect the remainder of the hydrant from damage.
3. It is equipped with an exclusive fire hydrant wrench, See TPMC Ref. No. F6852.
Available size (Source 3 with UL/FM)
| Inlet size | Way of outlet | Hose outlet | Pumper outlet | Flanged monitor elbow | Ref. No. |
|---|---|---|---|---|---|
| 6″ | 3-way | (2) 2-1/2″ NH | (1) 4-1/2″ NH | / | F0241 (UL/FM) |
Note:
1. The inlet base flange is available with ANSI B16.42 Class 150.
2. Traffic type (With breakable flange) breaks cleanly upon impact to protect the remainder of the hydrant from damage.
3. It is equipped with an exclusive fire hydrant wrench, See TPMC Ref. No. F6851.